Modline 5 is the latest and most advanced infrared
thermometer series in the IRCON lineup, built to
serve a wide range of industrial temperature
measurement applications. Designed with extensive
customer input and engineered with the expertise
that comes from over 45 years experience in the
business, Modline 5 offers advanced features
available with no other infrared thermometer series on the market.
NEW Series! Modline 5 56 Series
Sensor Highlights:
- NEW! -- 2 micron (2.0 - 2.8 or 2.3 - 2.6) and lower temperature (as low as
50° C / 122° F)
units to serve a wider range of applications
- NEW! -- Thermo-electrically cooled detector
- NEW! -- Internal self-calibration feature
Modline 5 Sensor Features:
-
Self-contained, Stand-Alone
infrared thermometer -- no remote electronics
needed for operation
-
PC software for remote sensor setup, configuration and monitoring included
-
Durable, sealed stainless
steel NEMA 4 housing
-
Total System Health Check diagnostics feature
verifies that the Modline 5 is working within factory
specifications
-
Innovative Match Function allows you to
input the process temperature (if known) and automatically
adjust emissivity
-
Our optional Dirty Window Detector
(DWD) checks the temperature sensor window to determine if there
is any build-up
-
A complete line of accessories
to help the Modline 5 perform in any temperature
sensing application
-
Easy-adjusting optics to focus
precisely on target
-
Built-In, thru-the-lens Visual or
Laser sighting
System Health Check
The Total System Health Check diagnostics tool lets the user verify
that the Modline 5 spot pyrometer is working within factory specifications.
By activating this check from the rear panel or remotely
via the Digital Panel Meter (DPM) the Total System
Health Check verifies that the temperature detector, internal
circuitry, and even the output signal are all working
with the original factory specifications for the sensor.
The Total System Health Check is a great verification
tool for preventative maintenance programs, start-up,
and application troubleshooting.
Dirty Window Detector (Pat. # 5812270)
Dirt, mist, dust, and other types of build-up can
affect the accuracy of any infrared thermometer regardless
of measurement wavelength. Traditionally it has been
up to the enduser to routinely clean the optics of
their sensor to ensure that the accuracy of their
measurement signal did not degrade too much. The optional
Dirty Window Detector (DWD) can sense build-up on
the window of the Modline 5 and provide an alarm output
to alert the user. Programmable coarse and fine parameters
within the Modline 5 setup menus let the user tune
the DWD depending on how severe their process is.
The DWD is an important option for those processes
that cannot tolerate fluctuations in accuracy or the
extremely dirty applications where the user wants
an alarm to notify his personnel that the sensing
window needs to be cleaned.
Match Function
Probably the most common question with non-contact
temperature measurement relates to the emissivity
of different materials. Now Ircon has taken away some
of the guesswork with the Match Function. The Match
Function is a standard feature of the Modline 5 Infrared
thermometer. If the user knows the exact process temperature
(usually verified with a thermocouple / RTD) then
they can program the temperature into the Modline
5 prior to start-up and AUTOMATICALLY adjust the emissivity.
Equations within the Modline 5 will calculate the
emissivity. It’s just that easy!
Specifications
| |
5R Series
|
52 Series
|
5G Series |
NEW: 56 Series |
| Temperature Range |
1112°-5432° F / 600°-3000° C |
932°-5432° F / 500°-3000° C |
482°-3632° F / 250°-2000° C |
112°-1472° F / 50°-800° C |
| Spectral Region |
0.85 – 1.05µ and 1.05µ
(Two Color) |
0.85 – 1.1µ |
1.5 – 1.6µ |
2.0 – 2.8µ |
Typical Applications |
Difficult high temperature
processes such as furnaces, kilns, molten
metals, thin wires or rods |
High temperature processes such as
metal forging, annealing, hardening and
foundries |
Ferrous and non-ferrous metal
treating applications |
Spot welding, induction heating
and lower temperature rubber, thick plastic or
textile applications |
Accuracy @ 25°C |
0.5% of Reading, + 2°C |
0.3% of Reading, + 12°C |
0.3% of Reading, + 1°C |
0.3% of Reading, + 1°C or 2°C (whichever is greater) |
| Response Time |
10 mS |
6.6 mS |
6.6mS |
10mS |
Emissivity / E – Slope
Range |
0.800 – 1.200 in .001 increments |
0.100 – 1.000 in .001 increments |
0.100 – 1.000 in .001 increments |
0.100 – 1.000 in .001 increments |
| Repeatability |
@ 25°C 0.1%
of Full Scale, +1 digit |
Inputs/Outputs
| Analog Output |
0-20mA, 4-20mA, 600 ohm max. |
| Analog Input |
4-20mA |
| Relay Output |
System alarm (24 VAC/DC @ 1 amp
resistive) |
| Digital Input/Output |
RS-485 (57.6k baud max.) |
| Power Requirements |
24 VDC +/- 10%, 8 Watts max. |
| Signal Processing Features |
Peak Picker, Track & Hold |
Physical
| Environmental Rating |
NEMA 4 (IP66) |
| Weight |
1.4 kg (3.1 lbs.) |
| Humidity |
10% to 90% non-condensing |
| Shock |
IEC 68-2-27 |
| Vibration |
IEC 68-2-6 |
| Sighting Methods |
Visible (through lens), Laser sighting |
Ambient Temperature
Without Cooling
|
0 to 55°C (32 to 130°F) |
| With Air Cooling |
0 to 120°C (32 to 250°F) |
| With Water Cooling |
0 to 200°C (32 to 400°F) |
| Storage Temperature |
-20 to 70°C (-4 to 160°F) |
Additional Options (Must be specified at
the time of order)
- Laser Sighting
- Dirty Window Detector
- Air Purge
- Base Mounting Adaptor
-
Digital Panel Meter
-
Multi-Sensor Interface
- Extension
Sleeve Adaptor (For use with DWD)
- Mounting Flange
(Small and Large)
- Power Supply
- Right Angle Mounting
- Water Jacket, Universal Adaptor
Please download the Modline 5 brochure for more information on
the full line of Modline 5 accessories.