The Mirage Infrared Thermometer consists of one IR Sensor, One
Indicator with panel mount hardware, one 12 foot or 4 meter
Interconnecting Cable, and one detailed Operations Manual. Complete
specifications and descriptions are shown in Catalog
MR-05. The 20, 60, and OR Series are also available
with fiber optic option. For details see Product Bulletin
PB-FOMR.
The Mirage Infrared Thermometer consists of a highly reliable
signal processing unit with a large and highly visible 4-digit
LCD display, and choice of five high performance sensor
series. Mirage infrared thermometers are ideal for
applications from 150°F to 6500°F (80°
to 3500°C) and feature adjustable response time
of 0.01 to 10 seconds, 1% accuracy and 0.3% repeatability
of full scale temperature.
- Choice of 4 Different Wavebands
- Through The Lens Viewing/Focusing
- Utilizes High Performance Temperature Detectors
- High Temperature Ratio Model (Two Color)
- Large LCD Display with PID Control
- High Optical Resolutions
- Fast Response Times
- On/Off Control Option
SPECIFICATIONS
TEMPERATURE SENSORS
Temperature Ranges and Optical Resolution
(See Catalog MR-05)
Input Power
From Indicator/Processor
Ambient Temperature Range
(without auxiliary cooling)
20 Series.....0 to 200°F......(-15 to 90°C)
30 Series.....32 to 140°F.....(0 to 60°C)
60 Series.....50 to 130°F.....(10 to 55°C)
OR Series.....32 to 130°F.....(0 to 55°C)
Relative Humidity: 10 to 90% non-condensing
TEMPERATURE INDICATOR/CONTROLLER
Accuracy
1% of full scale temperature or 10°F (6°C),
whichever is greater.
Repeatability
0.3% of full scale temperature ±1°.
Emissivity Control Ranges
Adjustable from 0.1 to 1.0 for all series, except OR Series.
Display
4-digit LCD with °F or °C display. Out of
range arrows and CAL display. OR Series has
invalid display indication. On/Off control option
has set-point display. Display updates every 1/2 second.
OR Series
E-Slope Adjustment: 0.85 to 1.15
Invalid Alarm: LCD display indication, plus relay
contact closure
Invalid Relay Contact Rating: 1 A at 24 Vdc
0.5 A at 120 Vac-Non-inductive load
Signal Reduction Range:
Above 1500°F (800°C) will tolerate approximately
95% reduction in radiation intensity (OR Series).
Response Time
10 milliseconds to 10 seconds adjustable.
Analog Outputs
0 to 10 Vdc non-isolated (3 mA max.) isolated option
available.
4 to 20 mA or 0 to 20 mA non-isolated (500 ohms load
max.)
isolated option available.
Power Requirements
100, 115, 200, 230 Vac ±10%, 50/60 Hz
Ambient Temperature Range
32 to 125°F (0 to 50°C)
10 to 90% R.H. non-condensing
Construction
Meets IEC-348 and NEMA 12K standards
OPTIONS
Peak Picker
Adjustable decay rate 0.01% to 5% of span per second.
A three-position control switch permits Off, Peaking,
or Reset functions, also Reset can be activated from
user supplied contact.
Two-Point On/Off Controller
Two Form-C relay outputs rated 3 A, 250 Vac resistive,
1 A, 250 Vac inductive. 30 millisecond response time
(5 millisecond additional for LR Series). The setpoint is
adjustable over the entire temperature range.
Hysteresis: 0.3% of span or 1°F (1°C) whichever
is greater
Isolated Analog Outputs
50 Vdc maximum differential between ground and optional
isolated outputs