The Ircon Javelin noncontact infrared thermometer is a compact,
highly versatile temperature sensor. With a stainless steel
body, plastic lens option, and temperature sensing capabilities
from 0°F to 1350°F (-20°C to 750 °C) the Javelin is the perfect
spot pyrometer for OEM, food, paper, and plastics applications.
- Economical Stand-Alone Infrared Thermometer
- Standard Focus (8” to 1000”) and Close Focus (4”
to 100”) designs
- User Selectable Peak Picker, emissivity, and response
time
- Stainless steel body is ideal for rugged industrial applications
- Optional plastic lens for sanitary processes (no
glass)
BASIC SYSTEM - Includes: IR temperature sensor and 3 meters
(10 foot) of cable. Ordering information and accessories
are listed below.
| Model
No. |
Spectral
Range |
Resolution
and Focus |
Temperature
Range |
| JAVS005C |
4.8 to 5.2µ |
D/30
Standard |
150
to750°C |
| JAVC005C |
4.8
to 5.2µ |
D/30
Close |
150
to 750°C |
| JAVS005F |
4.8
to 5.2µ |
D/30 Standard |
300
to 1350°F |
| JAVC005F |
4.8
to 5.2µ |
D/30
Close |
300
to 1350°F |
| JAVS079C |
7.5
to 8.5µ |
D/30
Standard
|
50
to 600°C |
| JAVC079C |
7.5
to 8.5µ |
D/30
Close
|
50
to 600°C |
| JAVS079F |
7.5
to 8.5µ |
D/30 Standard |
125
to 1200°F |
| JAVC079F |
7.5 to 8.5µ |
D/30
Close
|
125 to 1200°F |
| JAVS814C |
8
to 14µ |
D/30
Standard |
-20
to 550°C |
| JAVC814C |
8
to 14µ |
D/30
Close
|
-20
to 550°C |
| JAVS814F |
8
to 14µ |
D/30
Standard
|
0
to 1000°F |
| JAVC814F |
8
to 14µ |
D/30
Close
|
0
to 1000°F |
| JAVS814CP
** |
8
to 14µ |
D/10
Standard |
-20
to 550°C |
| JAVS814FP
** |
8
to 14µ |
D/10 Standard |
0
to 1000°F |
** Special
Plastic Lens for food and pharmaceutical applications
Accessories
Model
No.
Description
JAV000AP
Air Purge
JAV00AWC
Air/Water Cooler
JAV000MB
Mounting Bracket
JAV00LAD
Laser Aiming Device
Specifications
Length
7.8 in. (198 mm)
Width
1.5 in. (38 mm)
Construction
Sensor
Stainless steel
Sensor Cable
3 Meters (10 feet)
Electronics Housing
Rating
NEMA 4 (IP65)
Performance
Detector
Type
Thermopile
Optical Resolution
D/30
Focal Length
Standard
100 in. (2540 mm)
Close
8 in. (203 mm)
Calibration
Accuracy
±1% of reading, or ±4°F (2°C), (whichever is
greater)
Repeatability
±0.3% of reading or ±3°F (1.5°C)
Emissivity*
0.10 to 1.00 in 0.01 increments
Response
Time*
0.150; 0.40; 1.0; 3.0; 10 seconds
Peak
Picker*
On/Off; Decay rate: 0.1; 0.4; 1.0; 3.0; 10°C
or °F per second
* Note:
digitally adjustable
Electrical
Power
12 to 26 Vdc at 70 mA
Voltage
Output
0 to 10 Vdc, minimum load impedance, 500 K
ohms
Current
Output
4 to 20 mAdc, maximum loop impedance; 500 ohms
Environmental
Operating
Ambient Temperature
Range
0 to 60°C (without cooling)
0
to 150°C
(with air cooling)
0
to 200°C
(with water cooling)