Lowest Measured Temperature 1000°F / 550°C
Highest Measured Temperature 6000°F / 3400°C
Operating Wavelengths

0.70 to 1.0

 

The 1100 Series Infrared Thermometer is an accurate, reliable, and economical high temperature measurement device primarily used in the semiconductor industry. It provides a continuous, nonlinear, temperature-dependent output which can be used in conjunction with recording or controlling instrumentation. The optical components and silicon infrared detector are housed in a rugged, die cast, gasketed enclosure, allowing operation in the most severe industrial environments.

FEATURES

  • Response times as fast as 0.0015 second
  • High accuracy and repeatability
  • Fully automatic temperature compensation from 0 to 200°F (0 to 93°C)
  • Through-the lens sighting and focusing
  • High resolution optics provides for measuring of objects as small as 0.012" (0.3 Mm)
  • No power supply required
BASIC SYSTEM - Consists of one sensor, calibration module, 12 foot or 4 meter interconnecting cable, temperature verses output curve and detailed manual. Complete specifications and details are shown in PB-1100.

OPERATION

Every object emits infrared radiation as a function of its temperature. In the 1100 Series Pyrometer, an optical system spectrally selects the radiation from the object and focuses it onto a solid-state silicon detector. The detector generates an electrical signal proportional to the radiant intensity. The resulting nonlinear signal output provides a direct input for indicating and control devices. as shown in the picture, each Module is provided with a curve relating signal level with object temperature for its temperature range.

The 1100 Series Pyrometer utilizes the near end of the infrared spectrum, a narrow band centered at 0.9 micron. Operation in this spectral region overcomes the major sources of instrument error as follows:

  • Effects of atmospheric absorption bands such as water vapor and carbon dioxide are eliminated.
  • Errors caused by varying target emissivity are minimized.
  • Interference due to open clean flames is minimized.
A curve relating signal level with object temperature is provided for each Calibration Module supplied.

SPECIFICATIONS



Accuracy: 1% of Full-scale Temperature
Repeatability: 0.3% Full-scale Temperature
Spectral Response: 0.70 to 1.00 micron
Detector Type: Silicon
Response Time: 0.0015 second (1.5 ms) fastest response time available
Ambient Temperature Range: 0 to 200°F (-17 to 93°C). For ambient temperature above maximum limits, auxiliary cooling is recommended for rated accuracy.
Weight: 6.5 lbs (2.9 kg)